java.lang.Object | ||
↳ | com.datalogic.device.configuration.PropertyGroup | |
↳ | com.datalogic.decode.configuration.Code93 |
Code93
is the class that configures the Code 93 Symbology.
Fields | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Length1 | Length1 is one of the two configurable label lengths. |
||||||||||
Length2 | Length2 is one of the two configurable label lengths. |
||||||||||
enable | enable enables or disables the symbology. |
||||||||||
lengthMode | lengthMode is the LengthControlMode selected for a label. |
||||||||||
userID | userID specifies the symbology identifier (if any). |
Public Constructors | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
This is the constructor of Code93.
|
[Expand]
Inherited Methods | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
From class
com.datalogic.device.configuration.PropertyGroup
| |||||||||||
From class
java.lang.Object
|
Length1
is one of the two configurable label lengths. It can be used
as a single fixed accepted length, when lengthMode
is set to ONE_FIXED
.
When TWO_FIXED
is enabled, its value is one of the two possible accepted fixed lengths for a specific label.
It can also represent the minor or major length value whenever RANGE
is selected.
If is set below the accepted minimum, the smallest accepted length will be used; instead it the set value exceed the maximum value, the
biggest accepted length will be used.
Note: Length1
allowed range of values is somehow related to the nature of the barcode (linear vs 2D) but it's not intended to document
in any way the scanner capabilities. An accepted minimum value and an accepted maximum value are introduced only to simplify length management in the
device Scanner settings app. The chance to read a barcode depends on it's printed quality, resolution, overall size, distance from the reader,
environmental light, etc...
Length2
is one of the two configurable label lengths.
When TWO_FIXED
is enabled, its value is one of the two possible accepted fixed lengths for a specific label.
It can also represent the minor or major length value whenever RANGE
is selected.
If is set below the accepted minimum, the smallest accepted length will be used; instead it the set value exceed the maximum value, the
biggest accepted length will be used.
Note: Length2
allowed range of values is somehow related to the nature of the barcode (linear vs 2D) but it's not intended to document
in any way the scanner capabilities. An accepted minimum value and an accepted maximum value are introduced only to simplify length management in the
device Scanner settings app. The chance to read a barcode depends on it's printed quality, resolution, overall size, distance from the reader,
environmental light, etc...
lengthMode
is the LengthControlMode
selected for a label.
Selects the length control mode.
userID
specifies the symbology identifier (if any).
The symbology identifier is sent with the label when the
global decode property sendCodeId
is set to
USERDEFINED_IDENTIFIER_BEFORE_LABEL
or USERDEFINED_IDENTIFIER_AFTER_LABEL
.
This is the constructor of Code93. All symbology options are initialized by editor.
editor | A PropertyGetter used to load the current barcode family.
|
---|