Special Settings and Limitations
Special Settings for Magellan
Device | Setting |
---|---|
- Magellan 9900i/9600i - Magellan 900i - Magellan 9550i | • USB-COM must disable the CDC control endpoint (by setting the Disable value for the service command 074B) • USB-COM-SC must be configured so that RTS is held in low state and CTS is ignored (by setting the command 047B to value 00) |
Other Magellan devices | When connecting the device via USB-COM or USB-COM-SC interface, the command 0550 must disable the CDC control endpoint (set bit 4 to the value 1 - Block transmission of messages over control endpoint) |
Firmware Upgrade and Custom Configuration for the Old Magellan Devices (Magellan 1500i, Magellan 9800i, Magellan 34xx, Magellan 35xx)
Device | Setting |
---|---|
- Magellan 1500i - Magellan 9800i - Magellan 34xx - Magellan 35xx | As shown in section Supported Devices, Magellan 1500i, Magellan 9800i, Magellan 34xx, Magellan 35xx do not support Firmware upgrade and Custom configuration with the normal settings. However, you can execute the firmware upgrade and the custom configuration with the service cable (or the service mode). Plug the proper service cable or switch the device to service mode before using those features. |
Limitation of the Reset Command for Magellan 9600i and 9900i
Device | Setting |
---|---|
Magellan 9900i/9600i | The reset command of Magellan 9600i and 9900i can work properly on almost all the Android devices. However, after resetting Samsung tablets, Memor 12/17/30/35 devices, and Joya Smart, Datacapture SDK disconnects from the device. You need to unplug and plug the USB cable again to recover USB connection. |