Standard 2 of 5

 

 

Code Parameter

Description

I.D.#

C/C++ Define

Accept. Input

Defaults

Scanner Type

Min

Max

Factory

Laser

2D Imager

Lorax

 

Enter 1 for On and 0 for Off

Enable

Enables/disables the Standard 2 of 5 symbology.

0200

#define S25_ENABLE

On or Off

Off

On

Off

Enable

Aggressive

Decoding

Enables more aggressive decoding algorithms to be used in order to scan hard to read labels.

0201

#define S25_LEVEL

On or Off

Off

On

Off

 

 

Enable

Checksum

Requires the use of checksum characters to verify a bar code.

0202

#define S25_ENABLE_CHECK

On or Off

Off

Off

Off

 

 

Send

Checksum

Instructs the terminal to include the checksum in the label transmission.

0203

#define S25_SEND_CHECK

On or Off

Off

Off

Off

 

 

Use 2-bar Start/Stop

Allows the terminal to recognize labels that are printed using only two bars for start/stop characters.

0204

#define S25_2_BAR_START

On or Off

Off

Off

Off

 

 

Minimum

Label

Length

Set the minimum label length to be less than or equal to maximum label length.

0220

#define S25_MIN_LENGTH

01 - 50

01

01

06

Maximum

Label

Length

This feature specifies the maximum allowable length of a Standard 2 of 5 label. The length includes check and data characters. Maximum Label Length should be greater than or equal to Minimum Label Length.

0221

#define S25_MAX_LENGTH

01 - 50

01

50

10

Read

Verification

Sets the number of times a label must be read before it is transmitted.

0222

#define S25_REDUNDANCY

01 - 04

01

02

01

 

User ID

Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology.

0223

#define S25_USER_ID

Any

single

ASCII

character

(00 = Off)

 

‘F’

‘F’

‘F’