Code Parameter |
Description |
I.D.# |
C/C++ Define |
Accept. Input |
Defaults |
Scanner Type |
||||
Min |
Max |
Factory |
Laser |
2D Imager |
Lorax |
|||||
|
Enter 1 for On and 0 for Off |
|||||||||
Enable |
Enables/ disables the Matrix 2 of 5 symbology. |
0208 |
#define M25_ENABLE |
On or Off |
Off |
On |
Off |
√ |
√ |
|
Enable Aggressive Decoding |
Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. |
0209 |
#define M25_LEVEL |
On or Off |
Off |
On |
Off |
√ |
|
|
Enable Checksum |
Requires the use of checksum characters to verify a bar code. |
020A |
#define M25_ENABLE_CHECK |
On or Off |
Off |
Off |
Off |
√ |
√ |
|
Send Checksum |
Instructs the terminal to include the checksum in the label transmission. |
020B |
#define M25_SEND_CHECK |
On or Off |
Off |
Off |
Off |
√ |
√ |
|
Minimum Label Length |
Set the minimum label length to be less than or equal to maximum label length. |
0224 |
#define M25_MIN_LENGTH |
01 - 50 |
01 |
01 |
06 |
√ |
√ |
|
Maximum Label Length |
This feature specifies the maximum allowable length of a Matrix 2 of 5 label. The length includes check and data characters. Maximum Label Length should be greater than or equal to Minimum Label Length. |
0225 |
#define M25_MAX_LENGTH |
01 - 50 |
01 |
50 |
10 |
√ |
√ |
|
Read Verification |
Sets the number of times a label must be read before it is transmitted. |
0226 |
#define M25_REDUNDANCY |
01 - 04 |
01 |
02 |
01 |
√ |
√ |
|
User ID |
Specifies the symbology identifier (if any) that is sent by the decoder when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. |
0227 |
#define M25_USER_ID |
Any single ASCII character (00 = Off)
|
‘D’ |
‘D’ |
‘D’ |
√ |
√ |
|